google-site-verification=wws5UcLizKbH9Ox9h9qLZ__T3R1vXM0jqd_pr_Ofk4c

Above Ground Storage Tank (AST) / Sludge Conditioning

Bay Area Tank & Coating- BAT&C performed internal and external coatings on three (3) aboveground Storage tanks in Northern California.  One (1) Sludge Conditioning AST & Two (2) Polymer AST's.  After the crew was orientated they began to sandblast the 2 polymer tanks.  After the polymer tanks were blasted, BAT&C crew set up to internally line them with Enviroline 405 HT high-build two part epoxy coating system. After the polymer tanks were finished, BAT&C crew began blasting the Sludge Conditioning tank, clean and lined with Enviroline 405 HT high-build two part epoxy coating system.  All three of the tanks were externally coated with Sherwin Williams Macropoxy 646.   

image2-2.JPG

Above Ground / Underground Storage Tank (AST /UST) Repair

Before and after interior lining of Underground Storage Tank's (UST's)

January, 2015

BAT&C recently inspected and installed an interior lining system for a client in Eastern Washington on (5) five UST's (4) STI-p3 and (1) Split Clad Tank.  We de-gas, open and enter confined space; clean out interior of UST's and conduct inspection of the interior steel shell; install a monolithic epoxy lining system as preventative maintainance against corrosion, and reseal lid.

image2 (3).JPG
image2 (1).JPG

Before and after interior lining of Above ground Storage Tank's (AST's)

July, 2015 

BAT&C recently performed interior repair and installed interior lining in (2) two AST's in southern Oregon.  We clean out tanks, sandblast to near white metal profile, weld in patch plates to the floor, and install lining system in both AST's 18" up the sidewall and floor.

 

 

 



 

 

20150712_073132.jpg